Skip to main content

Deadband Auto Calibration

Location in toolbox: 
Tab Powerwheel open, waiting for motor parameters, motor should be in position mode to do Deadband Auto )>then tab Deadband Auto

Preparation

Before starting calibration:
Make sure that you have the correct firmware of the controller that supports this new function 2.7.8 firmware

  1. Warm up the engine and hydraulic system.
    The hydraulic steering system must be operating under normal conditions.
  2. Park the tractor on a flat surface.
  3. Straighten the front wheels.
  4. Follow and read instructions and pop-up windows from the toolbox.

How is correct and not correct installed  calibration sensor 

image.png


Wheel Calibration 0/2 means that calibration is not started 

After successfully completing the installation according to the instructions, click the Start button to begin auto-calibration for the first wheel.

After finishing calibration on the first wheel, move the sensor to the second wheel.
Wait 40 seconds to let the sensor stabilize and data settle, then press START to begin calibration on the second wheel.

image.png




After successful calibration, use the COPY button to save the deadband values and transfer them to the Navigation App in the tractor profile.

image.png

Result of positive flow succeeded.

image.png

Using the Deadband Value

  1. Open the Fieldbee navigation application.
  2. Go to Record Keeping> Vehicles.
  3. Find Calibrated tracktor and tap Edit.
  4. Tap the tractor angle field 8 times to open the Advanced Menu.